Flange Expansion Joints for a Thermal Power Plant

Flange Expansion Joints for a Thermal Power Plant

Expansion Joints that Required Helium Leak Testing

Expansion Joints that Required Helium Leak Testing

This order required custom engineering to design and manufacture these expansion joints due to their critical service condition requirements. PT&P manufactured and tested these expansion joints to the customer specifications, EJMA Standards and US Bellows Quality Standards.

Design Conditions:

-176 PSIG at 500˚F
-.5 Axial Extension and 1.5 Axial Compression
-18″ 304 Stainless Steel Expansion Joints with Special Designed and Machined Flange Faces with a Specially Designed Gasket Groove
-Special Customer Welding Requirements to A.W.S. Standards
Critical Spring Rate Requirements
-Stringent Testing Requirements: The Bellows Longitudinal Seams were 100% X-Rayed and Dye-Penetrant Examined. Each Expansion Joint was Helium Leak Tested to a Leak Rate of 1 x 10 ֿ 7

Categories: Single Expansion Joints Tags:
Comments are closed.
border

Contact Us: +1 (281) 241-9418 Toll Free: (855) 591-0906 Fax: +1 (713) 731-8640 sales@usbellows.com
Our Parent Company: Piping Technology Pipe Supports, Pipe Clamps, Pipe Hardware & Insulated Pipe Shoes
Fellow Subsidiaries: Sweco Fab: ASME Vessels, Pig Launchers, Duct Work, Strainers & Spectacle Blinds
 Pipe Shields: Pre-Insulated Pipe Supports, Slides, Guides & Anchors

Fronek Anchor/Darling
: Snubbers, Sway Struts & Sway Braces

Copyright © 2011  U.S. Bellows, Inc. All Rights Reserved. Privacy Policy