Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant — The Expansion Joints Blog
Home > Elbow Expansion Joints, Pressure Balanced Expansion Joints > Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

December 6th, 2006 John
 

Refurbishement of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

 

Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

US Bellows, Inc. refurbished two pressure balanced elbow expansion joints for a power generation plant with a quick turnaround during outages.

Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

Refurbishment of the Second of Two 54" Pressure Balanced Elbow Turbine Crossover Expansion Joints for a Power Generation Plant

The first 54″ outside diameter expansion joint leaked from a crack in the bellows causing an unscheduled power plant outage. This particular expansion joint was fabricated for a high pressure turbine crossover piping for steam service of 97 PSIG at 634°F. The 27′ long, 27,000 lb. expansion joint was refurbished in less than 4 weeks. This was made possible by utilizing dedicated employees working overtime 6 days a week. The 321 stainless steel bellows and carbon steel root rings were replaced. The outside cover bolts were removed and new bolts were installed.

The second expansion joint was also for a high pressure turbine that was replaced during a planned outage. This expansion joint came in on October 30, 2006 and was ready to ship November 20, 2006. Overall length and center line to center line length were maintained to ensure easy installation. Both expansion joints were dye-penetrant tested and hydro-tested at 146 PSIG.

Comments are closed.
border

Contact Us: +1 (281) 241-9418 Toll Free: (855) 591-0906 Fax: +1 (713) 731-8640 sales@usbellows.com
Our Parent Company: Piping Technology Pipe Supports, Pipe Clamps, Pipe Hardware & Insulated Pipe Shoes
Fellow Subsidiaries: Sweco Fab: ASME Vessels, Pig Launchers, Duct Work, Strainers & Spectacle Blinds
 Pipe Shields: Pre-Insulated Pipe Supports, Slides, Guides & Anchors

Fronek Anchor/Darling
: Snubbers, Sway Struts & Sway Braces

Copyright © 2011  U.S. Bellows, Inc. All Rights Reserved. Privacy Policy