1. Assume the following pipe expansion joint design criteria:
a) Line size: 16-inch nominal diameter.
b) Design/operating pressure: 160 psig.
c) Design/operating temperature: 450° F.
d) Movements/cycle life:
Installation: 0.25-inch compression; 0.125-inch extension; 0.0625-inch lateral; 0° angulation. Start-up/shut down: 1.0-inch compression; 0.25-inch lateral; 0°angulation; 300 cycles. Operating: 0.25-inch compression; 0.063-inch lateral; 1.0° angulation; 10,000 cycles.
e) End connections: 150 lb ANSI raised face slip-on flanges; ASTM A l05 (carbon steel).
f) Bellows material: A-240-T316.
g) Type: Single; unrestrained (i.e. no tie rods, hinge, or gimbal hardware).
h) Accessories: Liner and cover.
2. Turn to the Conversion Factor Graph and calculate equivalent catalog movements.