  Expansion Joint Product Testing: Hydro Testing

Objective: The objective of this test is check for leakage or cracks in the welding.
 
What we do: The bellows is completely filled with a liquid such as water. Pressure is slowly applied to the liquid until the required pressure is reached. This pressure is held for at least 30 minutes at which point the component is inspected visually to locate leaks.
 
After Completion: If a leak is present, the welds will be repaired after releasing the hydro test pressure.

 

Bellows are pressurized Pressure is observed

               

 
  
 

= Featured Product =


 
+ View larger images

  Go to featured product archives

U.S. Bellows, Inc. Designed and Fabricated 50 Universal Expansion Joints for an Air Force Base in New Mexico (Ref#91376-A1, EA) 11/14/2007
U.S. Bellows, Inc. fabricated 50 expansion joints from 304L stainless steel. The expansion joints were 6" and 8" sizes. The 6" expansion joints are 24" face to face and the 8" expansion joints are 26" face to face. All of the expansion joints are fabricated with liners that are also made with 304L stainless steel. The design temperature was 200°F and the design pressure was 200 PSIG. The expansion joints were dye-penetrant tested and hydro tested at 300 PSIG. U.S. Bellows, Inc. provides 100% customer satisfaction in terms of quality and delivery.

 